MP 81
Pumps suitable for emptying wells or cisterns, for gardening; entirely made of non-corrosive material.
CHARACTERISTICS:
- Handle, pump body and suction grille in polypropylene;
- Stainless steel engine jacket;
- Noryl impellers;
- Double lip seal;
- Crankshaft in AISI 416 steel with ceramic bushing;
- Ball bearings of;
- Liquid temperature 0 - 40°C;
- Equipped with 10 meters of H05 RNF cable;
- Available with or without float.
MOTOR:
- 2-pole induction electric motor suitable for continuous duty;
- Low specific loss stator laminations
- Class F insulation;
- IP 68 protection;
- Capacitor inserted inside.
Thermal protection for single-phase models; for three-phase models, it is the user's responsibility.
ON REQUEST:
Other operating voltages and frequencies; particular liquids.
DR 50-75-100
Drainage pumps with recessed impeller, Vortex or twin-channel type, for pumping wastewater and liquids with suspended solids; ideal for civil and domestic applications.
CHARACTERISTICS:
- Cast iron pump body with 1”1/2 ports;
- Vortex type cast iron impeller;
- Double seal with oil barrier;
- Silicon carbide pump side, sealing ring motor side;
- Crankshaft in AISI 416 steel;
- Ball bearings;
- Liquid temperature 0 - 40°C;
- Equipped with 10 meters of HO7 RNF cable;
- Available with or without float.
MOTOR:
- 2-pole induction electric motor in oil bath suitable for continuous duty;
- Low specific loss stator laminations;
- Class F insulation;
- IP 68 protection;
- Capacitor inserted inside;
- Thermal protection for single-phase models;
- For three-phase models, protection is the responsibility of the user.
ON REQUEST:
Other operating voltages and frequencies; Special liquids.
DR 150-200-300
Drainage pumps for dirty liquids with Vortex or twin-channel impeller for civil and industrial applications; they have been specifically designed for extremely heavy-duty use.
CHARACTERISTICS:
- Cast iron pump body with 2” threaded delivery port;
- Cast iron impeller;
- Double mechanical seal in silicon carbide with oil barrier on the pump side, graphite ceramic on the motor side;
- Crankshaft in AISI 304 steel for the hydraulic part;
- Ball bearings;
- Liquid temperature 0 - 40°C;
- Equipped with 10 meters of HO7 RNF cable;
- For single-phase models, the use of a control panel complete with start capacitor is required (35 µF for the 1.5 HP version, 40 µF for the 2 HP version).
MOTOR:
- 2-pole induction electric motor in oil bath suitable for continuous duty;
- Low specific loss stator laminations
- Class F insulation;
- IP 68 protection;
- Engine protection is the responsibility of the user.
ON REQUEST:
Other operating voltages and frequencies; particular liquids.
DR 200-300-400-550DN65
Drainage pumps for dirty liquids with Vortex or dual-channel impellers for civil and industrial applications; they have been specifically designed for extremely heavy-duty use; available for both mobile and fixed applications with coupling foot.
CHARACTERISTICS:
- Cast iron pump body with threaded delivery port DN 65;
- Cast iron impeller;
- Double mechanical seal in silicon carbide with oil barrier on the pump side, graphite ceramic on the motor side;
- Crankshaft in AISI 304 steel for the hydraulic part;
- Ball bearings;
- Liquid temperature 0 - 40°C;
- Equipped with 10 meters of HO7 RNF cable;
- For single-phase models, the use of a control panel complete with start capacitor is required (35 µF for the 1.5 HP version, 40 µF for the 2 HP version).
MOTOR:
- 2-pole induction electric motor in oil bath suitable for continuous duty;
- Low specific loss stator laminations
- Class F insulation;
- IP 68 protection;
- Engine protection is the responsibility of the user.
ON REQUEST:
Other operating voltages and frequencies; particular liquids.
CARPENTER
- Emptying of rainwater, infiltration water, wells or collection tanks.
- Collection from rainwater collection tanks for small
- surface irrigation of vegetable gardens and gardens.
- Transfer of clear water from tanks and basins.
- Pumping of dirty water with suspended solids (VOX series only).
CHARACTERISTICS:
20 mm - MIZAR 60 VOX; 75 VOX
Single-phase: 10 meters H07RN-F for normal version (auto-man)
5 meters H07RN-F for automatic version only
ON REQUEST: Special voltages and frequencies on request.
OPTIONAL: DN80 descent systems for fixed systems.
LOWER
- Emptying of rainwater, infiltration water, wells or collection tanks.
- Collection from rainwater collection tanks for small
- surface irrigation of vegetable gardens and gardens.
- Transfer of clear water from tanks and basins.
- Pumping of dirty water with suspended solids (VOX series only).

CHARACTERISTICS:
Single phase: 10 meters H07RN-F manual version only
ON REQUEST: Special voltages and frequencies on request.
OPTIONAL: DN80 descent systems for fixed systems.
VERTICAL
- Emptying of rainwater, infiltration water, wells or collection tanks.
- Collection from rainwater collection tanks for small
- surface irrigation of vegetable gardens and gardens.
- Transfer of clear water from tanks and basins.
- Pumping of dirty water with suspended solids (VOX series only).

CHARACTERISTICS:
20 mm - MIZAR 60 VOX; 75 VOX
Single-phase: 10 meters H07RN-F for normal version (auto-man)
ON REQUEST: Special voltages and frequencies on request.
OPTIONAL: DN80 descent systems for fixed systems.
TIGER
Emptying of settling pits and sewage collection wells. Pumping of wastewater, including those containing suspended solids and fibrous particles. Handling of wastewater for domestic and industrial use.

CHARACTERISTICS:
25° with PARTIALLY submerged pump;
35° with TOTALLY submerged pump;
35 mm - TIGER 80;
50 mm - TIGER 100 - 150 - 200;
Three-phase: 220-277V/50 or 380-480V/50Hz and 220-277V/60Hz or 380-480V/60Hz with user-provided overload protection.
Single phase: 10 meters H07RN-F for normal version (aut-man) 5 meters H07RN-F only for automatic version (excluding Tiger 150) 5 meters H05W-F only for Tiger 70
Three-phase: 10 meters H07RN-F
ON REQUEST: Special voltages and frequencies on request.
OPTIONAL: DN80 descent systems for fixed systems.
TENAX
Emptying of settling pits, cesspools, and sewage collection wells. Pumping of wastewater, including those containing suspended solids. Handling of wastewater for domestic and industrial use.

CHARACTERISTICS:
- Double chamber electric pump (mechanical seal motor);
- Single chamber electric pump (only for Tenax 440F-600F);
- Oil bath motor (biodegradable and dielectric) for cooling and bearing lubrication;
- Engine side sealing ring;
- Oil bath mechanical seal;
- Double mechanical seal (only for Tenax 400F - 600 F): oil-bathed motor side / water-bathed pump side;
- Maximum temperature of pumped liquid: 25° with PARTIALLY immersed pump / 35° with TOTALLY immersed pump;
- Passaggio libero: 50 mm - Tenax 150F a / 60 mm - Tenax 200F a / 50 mm - Tenax 300F a / 50 mm - Tenax 400F c / 50 mm - Tenax 600F c.
- Versions: Single-phase 220-277V/50Hz or 220-277V/60 Hz with built-in thermal protector and permanently inserted capacitor / Three-phase: 220-277V/50 or 380-480V/50Hz and 220-277V/60Hz or 380-480V/60Hz with overload protection to be provided by the user;
- Motor power: from 1.5 Hp to 2 Hp single-phase and three-phase versions / from 3 Hp to 6 Hp three-phase versions only;
- Automatic single-phase versions with float up to 1.5 HP / Manual-only single-phase versions from 2 HP without float;
- Standard cable: Single-phase: 10 meters H07RN-F for normal version (aut-man) / Three-phase: 10 meters H07RN-F.
ON REQUEST: Special voltages and frequencies on request.
OPTIONAL: DN80 descent systems for fixed systems.
ARVEX
Emptying of settling pits and sewage collection wells. Pumping of wastewater, including those containing suspended solids. Handling of wastewater for domestic and industrial use.

CHARACTERISTICS:
- Double chamber electric pump (mechanical seal motor);
- Single chamber electric pump (only for Tenax 440F-600F);
- Oil bath motor (biodegradable and dielectric) for cooling and bearing lubrication;
- Engine side sealing ring;
- Oil bath mechanical seal;
- Double mechanical seal (only for Tenax 400F - 600 F): oil-bathed motor side / water-bathed pump side;
- Maximum temperature of pumped liquid: 25° with PARTIALLY immersed pump / 35° with TOTALLY immersed pump;
- Passaggio libero: 50 mm - Tenax 150F a / 60 mm - Tenax 200F a / 50 mm - Tenax 300F a / 50 mm - Tenax 400F c / 50 mm - Tenax 600F c.
- Versions: Single-phase 220-277V/50Hz or 220-277V/60 Hz with built-in thermal protector and permanently inserted capacitor / Three-phase: 220-277V/50 or 380-480V/50Hz and 220-277V/60Hz or 380-480V/60Hz with overload protection to be provided by the user;
- Motor power: from 1.5 Hp to 2 Hp single-phase and three-phase versions / from 3 Hp to 6 Hp three-phase versions only;
- Automatic single-phase versions with float up to 1.5 HP / Manual-only single-phase versions from 2 HP without float;
- Standard cable: Single-phase: 10 meters H07RN-F for normal version (aut-man) / Three-phase: 10 meters H07RN-F.
ON REQUEST: Special voltages and frequencies on request.
OPTIONAL: DN80 descent systems for fixed systems.
CUTTER
Emptying of settling pits and sewage collection wells. Pumping of wastewater, including those containing suspended solids. Handling of wastewater for domestic and industrial use.

CHARACTERISTICS:
25° with PARTIALLY submerged pump /
35° with TOTALLY submerged pump;
Single phase 220-277V/50Hz or 220-277V/60 Hz with built-in thermal protector and permanently inserted capacitor (Cutter 140) / Three phase: 220-277V/50 or 380-480V/50Hz and 220-277V/60Hz or
380-480V/60Hz with user-supplied overload protection;
Single phase: 10 meters H07RN-F complete with electrical panel with 0.7 meter section without plug
Three-phase: 10 meters H07RN-F.
ON REQUEST: Special voltages and frequencies on request.
OPTIONAL: DN80 descent systems for fixed systems.
GRINDER
Pumping and grinding of wastewater containing solids and fibrous particles. Emptying of settling tanks, cesspools, and sewage collection pits. Handling of wastewater for domestic and industrial use.

CHARACTERISTICS:
bearing cooling and lubrication;
engine side in oil bath
water bath pump side
25° with PARTIALLY submerged pump;
35° with TOTALLY submerged pump;
Single phase 220-277V/50Hz or 220-277V/60 Hz with protector
built-in thermal and permanently inserted capacitor.
Trifase: 220-277V/50 o 380-480V/50Hz e 220-277V/60Hz o
380-480V/60Hz with overload protection by care
of the user.
from 3 Hp three-phase versions only
Single-phase 2 HP versions only manual without float;
Single phase: 10 meters H07RN-F
Three-phase: 10 meters H07RN-F
ON REQUEST: Special voltages and frequencies on request.
OPTIONAL: DN80 descent systems for fixed systems.